17. COM M E RC IAL APP LICATIONS:
(Only for those products that are designated for commer-
cial use by Pergo, Inc.)
In commercial applications, an expansion space of
1
2"is
required at all walls, pillars, pipes and other fixed objects.
Areas greater than 66 feet in length or width, and consec-
utive multiples of 66 feet, i.e. (one room; two or more
rooms with adjoining archways greater than 4 feet; large
room with extended hallway) must have a T-Molding
installed across the width of the room, archway or at the
beginning of the hallway to provide additional expansion
space.
When fastening fixtures to a floating floor, the anchoring
bolts or fasteners must have the same expansion space (
1
2
inch) around each bolt or fastener as required for walls,
pillars, pipes and other fixed objects.
Commercial flooring transitions that accommodate a
1
2"
expansion space are strongly recommended.
18. INSTALLING PERGO FLOORING ON STEP DOWN
AND
STAIR TRE AD APP LICATIONS: Pergo Stair Nosing is
used
to finish stair edges or step down applications. Prior
to beginning the installation, any loose or damaged
treads or risers should be repaired or replaced. The
stairs must be cleaned thoroughly from any loose
paint, debris, or old adhesives.
Due to the many varieties of stairs available in North
America, a professional stair contractor may be required
for certain installations. Check local building codes
before altering dimensions of stair tread, riser and nosing.
Should there be any questions regarding the application
of Pergo on stairs, please call our Customer Help line at
1-800 33-PERGO (1-800-337-3746).
STAIR NOSING
Step down from a floating floor
Cut the Pergo stair nosing to the desired length. The
nosing must be fastened with screws (ie. finishing
screw #6 by at least 1
1
8"). A quality construction
adhesive should also be used. A
1
4" expansion space
must be maintained between the nosing and the
floating floor. For Step Down (from a floating floor ) to
a lower level or at the top of a flight of stairs: Adhere
the stair nosing with a quality construction adhesive
and with #6 finishing screws 1
1
8" in length. Place
screws 2 inches from each end of the nosing and
space additional screws at intervals no greater than
8 inches along the length of the nosing.
a. For
5
16" (8mm) plank thickness use the thin shim
beneath the stair nosing. Adhere the shim to the
nosing with construction adhesive and adhere
the shim and nosing to the subfloor with construc-
tion adhesive and fasten with screws
b. For
3
8" (9-11mm) plank thickness use the thick
shim beneath the stair nosing. Adhere the shim
to the nosing with construction adhesive and
adhere the shim and nosing to the subfloor with
construction adhesive and fasten with screws
Stair Treads only: Adhere the stair nosing with a quality
construction adhesive and fasten with #6 finishing screw
1
1
8" in length. Place screws 2 inches from each end of
the nosing and space additional screws at intervals no
greater than 8 inches along the length of the nosing.
For
5
16" (8mm) plank thickness do not place any shim
beneath the stair nosing. Adhere the stair nosing
directly to the tread with construction adhesive and
fasten with screws
For
3
8" (9-11mm) plank thickness use the thin shim
beneath the stair nosing. Adhere the shim to the
nosing with construction adhesive and adhere the
shim and nosing to the tread with construction adhe-
sive and fasten with screws
For
5
16" (8mm) plank thickness with an attached
underlayment foam use the thin shim beneath the
stair nosing. Adhere the shim to the nosing with con-
struction adhesive and adhere the shim and nosing
to the tread with
construction adhe-
sive and fasten with
screws
This illustration shows the
step down from a float-
ing floor. The step down shows the tread flush or even
with the riser.
Tread flush or even with the riser
The riser must be installed before the stair nosing is fit
into place. If installing from a floating floor, follow the
above instructions. When installing on a stair tread,
the nosing will be
installed after the tread
and riser are glued into
place.
Tread with an extend-
ed round edge nosing
The rounded portion
of the extended nosing will need to be squared.
Leave as much of the extending nose of the tread as
possible, removing only the radius (the rounded por-
tion). On the edge of the squared nosing, glue a nar-
row strip of Pergo. This will finish the exposed edge of
the tread. After installing the tread and riser the nos-
ing will be installed, finishing the nose of the tread.
The illustration shows a step with an extended round
edge nosing. On the illustration a dotted line will
show where to cut the rounded portion of the
extended nosing.